Print Back
Available versions: Standard; CANopen; ATEX; CSA; IECEx; Schiff & Offshore; with HSI sensor detection; with front-flush diaphragm; for applications with increased functional security.

The pressure transducer series HDA 4700 is equipped with a very accurate and robust sensor cell with a thin-film DMS on a stainless steel diaphragm. The 4 to 20 mA or 0 to 10V output signals enable connection to all measurement and control devices of HYDAC ELECTRONIC GmbH and linkage to commercially available evaluation systems (e.g. PLC controls). The variant with HSI sensor detection was specially developed for use in conjunction with the HYDAC measurement devices HMG 500, HMG 510, HMG 3000 and CMU 1000. For data transmission purposes, the EVS 4748-H is equipped with an HSI interface (HYDAC Sensor Interface). Thanks to this, the HSI sensor is recognized completely automatically by the HYDAC measurement devices listed above and all necessary basic device settings are then immediately undertaken automatically. The variant with the front-flush diaphragm was specially developed for applications in which the media used could lead to a blockage, gumming-up or freezing of a standard pressure connection. The variant for applications with enhanced functional safety was specially developed for use in safety circuits / safety functions in the context of the functional safety of machines and plants up to PL d - Cat 3 (in accordance with ISO 13849). In addition, utilization in an SIL 2 - system (in accordance with EN 61508) is also possible. The pressure transducers are designed with two channels. Each channel consists of one sensor element and one evaluation electronics. Because of this, the pressure transducer generates two separate pressure-proportional output signals which are independent of one another. The main areas of application are in the mobile or industrial area of hydraulics and pneumatics, particularly in applications with constricted cavity and as sensor elements in mobile, safety-oriented systems such as load torque display or load torque limitation in loading cranes or work platforms. Additional fields of application can be found in processes with changing media, in which residues could lead to mixing or contamination of the media.
HDA4
Unit of Measure
1 

Item #

Item Name

Pressure [Max]

Housing Material

Burst Pressure

Minimum Lead Time

909429 N/A HDA 4748-H-0009-000 N/A 20 bar290 psi N/A Stainless Steel N/A 100 bar1450 psi N/A
909425 N/A HDA 4748-H-0016-000 N/A 32 bar464 psi N/A Stainless Steel N/A 200 bar2900 psi N/A
909554 N/A HDA 4748-H-0060-000 N/A 120 bar1740 psi N/A Stainless Steel N/A 300 bar4351 psi N/A
909426 N/A HDA 4748-H-0100-000 N/A 200 bar2900 psi N/A Stainless Steel N/A 500 bar7250 psi N/A
909337 N/A HDA 4748-H-0250-000 N/A 500 bar7251 psi N/A Stainless Steel N/A 800 bar11603 psi N/A
909427 N/A HDA 4748-H-0400-000 N/A 800 bar11603 psi N/A Stainless Steel N/A 1000 bar14503 psi N/A
909428 N/A HDA 4748-H-0600-000 N/A 1000 bar14503 psi N/A Stainless Steel N/A 2000 bar29000 psi N/A
925048 N/A HDA 4346-A-0016-EN1-007-F1 N/A 32 bar464 psi N/A Stainless Steel N/A 200 bar2900 psi N/A
Unit of Measure