Range of eleven evenly spaced sizes.
Visual thermometer with ºC and ºF scale.
Temperature gauge which measures the temperature of the operating fluid in the tank in ºC. Dual scale in ºC and ºF available on request.
Simple standardized installation conditions.
Unit of Measure

Specifications

Type

N/A Fluid Level Gauges

Seal Material

N/A Soft Seals in Viton (FKM) or Perbunan (NBR)

Weight

N/A 0.19 kg

Operating Temperature [Min]

N/A -20 ºC

Operating Temperature [Max]

N/A 80 ºC

Operating Pressure [Max]

N/A 0.5 bar

Mounting Type

N/A Fluid Tank

Operating Fluids

N/A Mineral oil to DIN 51524 Part 1 and 2, water-oil emulsions and synthetic fluids, such as hydraulic fluids based on phosphate ester. (other fluids on request)

Housing Frame

N/A Aluminum (Steel or Stainless Steel on Request)

Installation

N/A Vertically on the Tank Wall

Flow Direction

N/A Any

Bolts, Nuts, and Washers Material

N/A Steel

Bolts, Nuts, and Washers Finish

N/A Zinc-Plated

Connectors and Tube Material

N/A High Quality Synthetic Material

Tightening Torque (Dry)

N/A 8 N·m

Tolerance for Tightening Torque (Dry)

N/A -0.5 N·m

Tightening Torque (Lubricated)

N/A 6 N·m

Tolerance for Tightening Torque (Lubricated)

N/A 0.5 N·m

Dimensions

Banjo Bolt Thread

N/A M12

Thread Length [Min]

N/A 6 mm

Dimension L1

N/A 88 mm

Nominal Centre Distance of Bolts L2

N/A 127 mm

Tolerance for Nominal Centre Distance of Bolts L2

N/A ± 0.3 mm

Length

N/A 159 mm

Connection Type

Connection Type

N/A The device is mounted using two banjo bolts. The connection bores can be either threaded holes or through holes (Ø 13, Ø 11).

Application

Application

N/A Fluid level gauges FSA, fluid level sensors FSK and temperature switches TS are used to monitor and control levels of operating fluid.

Areas of application are for example: Machine tools, system engineering, tanks for hydraulic, lubricating and cutting oils, and gearboxes.

Construction

Construction

N/A The devices are designed to be mounted directly on to the operating fluid tank

Function

Function

N/A By using the FSA, the fluid level can be easily seen on the outside of the tank. The fluid enters the unit via the lower connection bore and is clearly visible in the tube. By selecting the right size, the particular fluid level can be monitored.

Additional Information

Additional Information

N/A The upper viscosity limit is 2,000 mm²/s. It is not possible to combine a TS temperature switch with an FT temperature gauge.

To ensure correct functioning, pressure, viscosity and temperature specifications must be observed.

In the standard design not suitable for use with glycol and fluids containing glycol - the special design SO14 is recommended as a solution variant in such cases.

The display tube must not be brought into direct contact with cleaning agents or solvents which are used to clean containers / tanks. Prior damage/new damage of the display tube may lead to failure of the FSA.

Note

Note

N/A The information in this brochure relates to the operating conditions and applications described. For applications and operating conditions not described, please contact the relevant technical department.

The operator is always responsible for determining the product suitability for the specific application. Quantified values for product characteristics are average values for a new product that undergo a time deterioration process.

Subject to technical modifications and errors.