	Base-Ported Medium Pressure Filters, 500 - 1500 psi (35 - 100 bar)
	base-ported-medium-pressure-filters
	
- 
		K9 Base-Ported Filters, 900 psi (60 bar), 100 gpm (380 l/min)		
		
		
		- Extremely versatile multiple inlet and outlet ports; can be used alone or in series with another K9
- Top loading for easy access for element change-out
- Allows consolidation of inventoried replacement elements by using K-size elements
- Multiple inlet and outlet porting options reduce the need for additional adaptors on installation
- Can be fitted with test ports for oil sampling
- Small profile allows filter to be mounted in tight areas
- Various Dirt Alarm® options
- Meets HF4 automotive standard
 
- 
		GK9 GeoSeal® Base-Ported Filters, 900 psi (60 bar), 100 gpm (380 l/min)		
		
		
		- Extremely versatile multiple inlet and outlet ports; can be used alone or in series with another K9
- Top loading for easy access for element change-out
- Allows consolidation of inventoried replacement elements by using K-size elements
- Multiple inlet and outlet porting options reduce the need for additional adaptors on installation
- Can be fitted with test ports for oil sampling
- Small profile allows filter to be mounted in tight areas
- Various Dirt Alarm® options
- Meets HF4 automotive standard
 
- 
		2K9 Base-Ported Filters, 900 psi (60 bar), 100 gpm (380 l/min)		
		
		
		- Two patent-pending K9 filters supplied in series as a single filter assembly providing in-line single pass particulate and water filtration
- Meets HF4 automotive standard
- 900 psi rating covers almost all transfer line pressure specs including air driven transfer systems
- Top loading for easy access for element change out
- Allows consolidation of inventoried elements by using K-size elements
- Can be fitted with test points for oil sampling
 
- 
		3K9 Base-Ported Filters, 900 psi (60 bar), 100 gpm (380 l/min)		
		
		
		- Three patent-pending K9 filters supplied in series as a single filter assembly providing in-line single pass particulate and water filtration
- Meets HF4 automotive standard
- 900 psi rating covers almost all transfer line pressure specs including air driven transfer systems
- Top loading for easy access for element change out
- Allows consolidation of inventoried elements by using K-size elements
- Can be fitted with test points for oil sampling
 
- 
		G3K9 GeoSeal® Base-Ported Filters, 900 psi (60 bar), 100 gpm (380 l/min)		
		
		
		- Three patent-pending K9 filters supplied in series as a single filter assembly providing in-line single pass particulate and water filtration
- Meets HF4 automotive standard
- 900 psi rating covers almost all transfer line pressure specs including air driven transfer systems
- Top loading for easy access for element change out
- Allows consolidation of inventoried elements by using K-size elements
- Can be fitted with test points for oil sampling
 
- 
		QF5 Base-Ported Filters, 500 psi (35 bar), 300 gpm (1135 l/min)		
		
		
		- Element change out from the top minimizes oil spillage
- Available with optional core assembly to accommodate coreless elements
- Offered with standard Q, QPML deep-plated and QCLQF coreless elements in a 39" length with standard Viton® seals
- Offered in pipe, SAE straight thread, and flange porting
- Integral inlet and outlet test points are standard in all models
- WQF5 model for water service also available
- Various Dirt Alarm® options
 
- 
		2QF5 Base-Ported Filters, 500 psi (35 bar), 300 gpm (1135 l/min)		
		
		
		- Two QF5 filters supplied in series as a single filter assembly providing in-line single pass particulate and water filtration
- Element changeout from the top minimizes oil spillage
- Available with optional core assembly to accommodate coreless elements
- Offered with standard Q, QPML deep-plated and QCLQF coreless elements in 16" and 39" lengths with standard Viton® seals
 
- 
		QF5i Cold Start Protection Inside-Out Flow, 500 psi (35 bar), 120 gpm (454 l/min)		
		
		
		- Magnetic filtration protection while filter is in cold start bypass
- Coreless QCL element with inside-out flow for eco-friendly, easy disposal
- Efficient means to remove both ferromagnetic and non-ferronmagnetic parts from the fluid
- Designed for inside-out flow
 
- 
		3QF5 Base-Ported Filters, 500 psi (35 bar), 300 gpm (1135 l/min)		
		
		
		- Element change out from the top minimizes oil spillage
- Available with optional core assembly to accommodate coreless elements
- Offered with standard Q, QPML deep-plated and QCLQF coreless elements in a 39" length with standard Viton® seals
- Offered in pipe, SAE straight thread, and flange porting
- Integral inlet and outlet test points are standard in all models
- WQF5 model for water service also available
- Various Dirt Alarm® options
 
- 
		QFD5 Base-Ported Filters, 500 psi (35 bar), 350 gpm (1325 l/min)		
		
		
		- Duplex filter design
- Approved for API 5L use
- Element change out from the top minimizes oil spillage
- Available with optional core assembly to accommodate coreless elements
- Offered with standard Q, QPML deep-pleated and QCLQF coreless elements in 16" and 39" lengths with Viton® seals as the standard
- Offered in 2" and 3" SAE J518 4-bolt flange Code 61 and ANSI 300# flange porting
- Integral inlet and outlet test points are standard on all models
- WQLF15 model for water service also available
- Various Dirt Alarm® options
- Also available in 4, 6 or 8 housing modular designs
 
- 
		QF15 Base-Ported Filters, 1500 psi (100 bar), 450 gpm (1700 l/min)		
		
		
		- Also available in L-ported version
- Element change out from the top minimizes oil spillage
- Available with optional core assembly to accommodate coreless elements
- Offered with standard Q, QPML deep-pleated and QCLQF coreless elements in 16" and 39" lengths with Viton® seals as the standard
- Offered in pipe, SAE straight thread, and flange porting
- Integral inlet and outlet test points are standard on all models
- Various Dirt Alarm® options
 
- 
		QLF15 Base-Ported Filters, 1500 psi (100 bar), 500 gpm (1900 l/min)		
		
		
		- In-line version also available
- Element change out from the top minimizes oil spillage
- Available with optional core assembly to accommodate coreless elements
- Offered with standard Q, QPML deep-pleated and QCLQF coreless elements in 16" and 39" lengths with Viton® seals as the standard
- Offered in pipe, SAE straight thread, and flange porting
- Integral inlet and outlet test points are standard on all models
- WQLF15 model for water service also available - refer to Section 7 of this catalog
- Various Dirt Alarm® options
 
- 
		SSQLF15 Base-Ported Filters, 1500 psi (100 bar), 500 gpm (1900 l/min)		
		
		
		- Also available in L-ported version
- Element change out from the top minimizes oil spillage
- Available with optional core assembly to accommodate coreless elements
- Offered with standard Q, QPML deep-pleated and QCLQF coreless elements in 16" and 39" lengths with Viton® seals as the standard
- Offered in pipe, SAE straight thread, and flange porting
- Integral inlet and outlet test points are standard on all models
- Various Dirt Alarm® options
 
 
                        