- Variety of differential indicator port options (visual and electrical indicators)
- Leak proof bar indicator, rugged visual indicator with protective aluminum shield is standard
- Proprietary bowl to element seal - minimizes potential leakage point by use of one seal on element
- Cartridge style element (non spin-on) that is proprietary and patented with integrated bypass valve features
- Wide variety of media grades that can be application specific
- Light weight bowl design with replaceable element minimizes landfill waste
- Mounting interchangeability with competitor's filter head
- The inherent capability to pre-print the perforated outer element wrap provides a branding solution that helps to capture after-market replacement element sales
                    Unit of Measure
                    
               
        
            Specifications
| Type | N/A Top-Ported Medium Pressure Return Line HydraSPIN Filters | 
| Style | N/A Top Ported | 
| Seal Material | N/A Buna | 
| Application | N/A Hydraulic and Lube | 
| Size | N/A 11G | 
| Material | N/A Excellement® Z-Media® (Synthetic) | 
| Class | N/A 10 | 
| Mounting Type | N/A Top Ported | 
| Head Material | N/A Porting Head: Die Cast Aluminum | 
| Designation | N/A Single | 
| Indication Type | N/A VM = Visual Pop up w/ Manual Reset | 
| Connection Gender | N/A SAE-24 | 
| Bowl Material | N/A Element Case: Aluminum | 
| Medium | N/A Petroleum Based Fluids All E media (cellulose), Z-Media® (synthetic) and H media (Hydraspin) | 
| Flow | N/A 35 gpm132 L/min | 
| Cracking Pressure | N/A 1.7 bar25 psi | 
| Filter Rating | N/A 10 µm | 
| Fatigue Pressure | N/A 50 bar725 psi | 
| End Type | N/A SAE | 
| End Size | N/A SAE-24 | 
| Short Description | N/A Top-Ported Medium Pressure Return Line Filters | 
Features
| Features | N/A Leak proof bar indicator, rugged visual indicator with protective aluminum shield is standard. Proprietary bowl to element seal - minimizes potential leakage point by use of one seal on element. Cartridge style element (non spin-on) that is proprietary and patented with integrated bypass valve features. | 
 
                        