Features and Benefits
  • Base-ported pressure filter
  • Can be installed in vertical or horizontal position
  • Meets HF4 automotive standard
  • Element changeout from top minimizes oil spillage
  • Offered in pipe, SAE straight thread, flanged and ISO 228 porting
  • No-Element indicator option available
  • Available with non-bypass option with high collapse element
  • Integral inlet and outlet female test points option available
  • Offered in conventional subplate porting
  • Same day shipment model available
  • Double and triple stacking of K-size elements can be replaced by single KK or 27K-size elements
  • Available with quality-protected GeoSeal® Elements (GKF30/GKF50)

Modify Configuration

Item #
Item #
Disclaimer
Filter Series
KF50 KFN50
Number & Size of Elements
  • 1: 27K
  • 1: K
  • 1: KK
  • 2: K
  • 3: K
Media Type
  • AS: Anti-Stat Media (Synthetic)
  • E media (cellulose)
  • M: Media (reusable metal mesh)
  • W: W Media (water removal)
  • Z: Excellement® Z-Media® (synthetic)
  • ZW: Aqua-Excellement® ZW Media
  • ZX: Excellement® Z-Media® (high collapse center tube)
Micron Rating
  • 3: 3 Micron (AS, E, Z, ZW, ZX media)
  • 10: 10 Micron (AS, E, M , Z, ZW, ZX media)
  • 25: 25 Micron (E, M, Z , ZW, ZX media)
Seal Material
  • Buna N
  • H.5: Skydrol® Compatibility
  • H: EPR
  • V: Viton®
Magnet Option
  • M: Magnet inserts (not available w/ indicator in cap)
  • None
Porting
  • F: 1 1/2" SAE 4-bolt flange Code 61
  • P: 1 1/2" NPTF
  • P32: 2" NPTF
  • S: SAE-24
  • O: Subplate
  • B24: ISO 228 G-1 1/2"
Test Point
  • None
  • L: Two 1/4" NPTF inlet and outlet female test ports
  • U: Series 1215 7/16 UNF Schroeder Check Test Point installed in cap (upstream)
  • UU: Series 1215 7/16 UNF Schroeder Check Test Point installed in block (upstream and downstream)
Indicator
  • None
  • D: Pointer
  • D5: Visual pop-up
  • D5C: D5 in cap
  • D8: Visual w/ thermal lockout
  • D8C: D8 in cap
  • D9: All stainless D5
  • MS: Cam operated switch w/ 1/2" conduit female connection
  • MS5: Electrical w/ 12 in. 18 gauge 4-conductor cable
  • MS5LCT: Low current MS5T
  • MS5LC: Low current MS5
  • MS5T: MS5 (see above) w/ thermal lockout
  • MS10: Electrical w/ DIN connector (male end only)
  • MS10LC: Low current MS10
  • MS10LCT: Low current MS10T
  • MS10T: MS10 (see above) w/ thermal lockout
  • MS11: Electrical w/ 12 ft. 4-conductor wire
  • MS12: Electrical w/ 5 pin Brad Harrison connector (male end only)
  • MS12LC: Low current MS12
  • MS12LCT: Low current MS12T
  • MS12T: MS12 (see above) w/ thermal lockout
  • MS13DC: Supplied w/ threaded connector and light
  • MS13DCLCT: Low current MS13DCT
  • MS13DCT: MS13 (see above), direct current, w/ thermal lockout
  • MS14DC: Supplied w/ 5 pin Brad Harrison connector and light (male end)
  • MS14DCLCT: Low current MS14DCT
  • MS14DCT: MS14 (see above), direct current, w/ thermal lockout
  • MS16: Electrical w/ weather-packed sealed connector
  • MS16LC: Low current MS16
  • MS16LCT: Low current MS16T
  • MS16T: MS16 (see above) w/ thermal lockout
  • MS17LC: Electrical w/ 4 pin Brad Harrison male connector
  • MS17LCT: Low current MS17T
Additional Options
  • None
  • C: Electrical indicator in cap vs. in base standard
  • G509: Dirt Alarm and drain opposite standard
  • G588: Electric Switch and drain opposite standard
  • N: No-Element Indicator (not available w/ Non-Bypassing and GeoSeal options or housings w/ indicator in cap)